Factory re-flash TEMP-1B

If your device becomes unresponsive and you've exhausted the other troubleshooting methods you can reflash the factory firmware by following the below guide.

This needs to be done in Chrome, Edge, or another Chromium based browser.

If your device has already been added to Homey, please remove it from Homey before continuing.

1. Put your device in boot mode by holding down the boot button and then plugging in the USB cable.

2. Navigate to the Apollo TEMP-1 installer. The TEMP-1B uses the same page as the TEMP-1.

Remove the battery!

This will not work properly if the battery is still supplying power to the TEMP-1B. Please remove the battery if you are having issues!

3. Choose Battery Power since you are using a TEMP-1B, then click Connect & Install.

TEMP-1 page of the Apollo installer with the Battery Power variant and the Connect & Install button outlined in red

Use R2 version unless instructed to use R1 by support!

The Apollo installer installs the Revision 2 (R2) firmware. R2 is what all of our devices use except a very small batch of TEMP-1 and TEMP-1B boards. If support tells you your board needs Revision 1 (R1), click Connect under Battery Firmware Revision 1 on the classic TEMP-1 installer instead. In the next steps, the firmware option is named Install ApolloAutomation.TEMP-1B.

4. Select the open com port then click Connect.

Browser serial port dialog with the USB JTAG/serial debug unit port selected and the Connect button

5. Click Install Apollo.TEMP-1B_R2.

Device Dashboard dialog with the TEMP-1B firmware install option selected

6. Click "INSTALL".

TEMP-1B firmware install confirmation dialog with the cursor on the Install button

7. Once you see "Installation complete!" you are finished. Click Next then close out of the browser window.

Web installer dialog showing Installation complete after flashing the TEMP-1B, with the Next button

Power cycle your device before doing anything else!

Your device is still in boot mode and needs to be power cycled aka power removed to make it boot in a normal mode!

8. Please proceed to the getting started guide and set up your sensor as a new device!