Skip to content

Sensor Definitions

Once added to Home Assistant you can configure different settings for your PUMP-1. Use the tabs below to see what each entity does, grouped the same way Home Assistant displays them.

How often readings update

The Default Update column is how often each entity refreshes. The Fluid Input and Fluid Output sensors are event-driven, so they report the moment water rises above or falls below the sensor rather than on a fixed interval.

Control What it does
RGB Light One RGB Neopixel LED. Click the light bulb or color wheel to change the color. Use the toggle to turn it on or off.
Pump Run Seconds Amount of time in seconds to run the pump when you press Run Pump. Range is 1 to 120 seconds. Defaults to 10s.
Run Pump Runs the PUMP-1 pump for the number of seconds set in Pump Run Seconds.
Run Pump Until Output Wet Runs the pump until the Fluid Output sensor changes to Wet. Disabled by default.
Sensor Default Update Details
Fluid Input on change Ultrasonic sensor at the bottom of the PUMP-1 water bottle that monitors the presence of fluid. Reports Wet while water is present and Dry once the bottle is empty.
Fluid Output on change Ultrasonic sensor you can mount on the exterior of any container to detect water on the other side, such as a Keurig reservoir or fish tank. Reports Wet when the water level is above the sensor and Dry when it falls below.
Setting Default What it does
ESP Reboot Restarts the device. Helpful for troubleshooting or refreshing the connection.
Max Safe Run Time 60 s Maximum time the pump will run before shutting off. Range is 5 to 600 seconds.
Pump Control Toggles the pump on and off via a switch. Still stopped by Max Safe Run Time. Disabled by default.
Stop Pump When Input Dry Off Turns the pump off when the ultrasonic sensor at the bottom of the water bottle detects no water. This check is automatically skipped when Invert Water Logic is enabled.
Stop Pump When Output Wet Off Turns the pump off when the Fluid Output sensor (mounted on a Keurig tank, fish tank, or similar container) detects that the water level has risen above its monitoring point.
Invert Water Logic Off Flips the meaning of the Fluid Input sensor so that Dry = destination is low (start pumping) and Wet = destination is full (stop pumping). Use this when the Input sensor is placed at the low-water mark inside a destination tank (for example, a CPAP reservoir) rather than at the bottom of a supply bottle. Disabled by default.
Auto Refill Off When enabled together with Invert Water Logic, the pump automatically starts a fill cycle whenever the Fluid Input sensor reads Dry. The pump stops when the Fluid Output sensor reads Wet or when Max Safe Run Time is reached, whichever comes first. Requires Invert Water Logic. Disabled by default.
Pump Safety Override Off Disables the safety features. Disabled by default.
Factory Reset ESP Erases settings and returns the device to factory firmware defaults. Disabled by default.
Entity Default Update What it shows
Apollo Firmware Version on boot The Apollo firmware build installed on the device (for example, 26.3.2.1).
ESPHome Version on boot The ESPHome version the firmware was compiled with.
Firmware Update Shows whether a firmware update is available and lets you update from inside Home Assistant.
IP Address on connect The device's IP address on your network.
Online on change Connection status of the device to Home Assistant.
RSSI 60s Wi-Fi signal strength in dBm. Values closer to 0 are stronger; a weak signal can affect reliability.
ESP Temperature 60s Internal temperature of the ESP32 chip. Runs warmer than the room because of the processor and Wi-Fi radio. Disabled by default.
Uptime 60s How long the device has been running since its last reboot.