Sensor Definitions
Once added to Home Assistant you can configure different settings for your R-PRO-1. Use the tabs below to see what each entity does, grouped the same way Home Assistant displays them.
The R-PRO-1 pairs two radars: an LD2450 that tracks the position of up to three targets and reports zone occupancy, and an LD2412 that handles presence and per-gate sensitivity tuning. It also carries an LTR390 light sensor and an optional SCD40 CO₂ module.
How often readings update
The Default Update column is how often each entity refreshes. Radar entities update in real time as targets move. The SCD40 and LTR390 sensors report every 60s.
Controls Sensors Configuration Diagnostic
Control
What it does
RGB Light
Four RGB Neopixel LEDs. Click the light bulb or color wheel to change the color. Use the toggle to turn them on or off.
Calibrate SCD40 To 420ppm
Forces a fresh-air calibration of the SCD40 CO₂ sensor to the outdoor baseline (about 420 ppm ). Run it outdoors or next to an open window.
Air quality & light
Sensor
Default Update
Details
CO2
60s
True NDIR reading from the SCD40. Shows Unknown if you do not have the CO₂ module. You can re-calibrate it to the outdoor baseline .
SCD40 Temperature
60s
Temperature from the optional SCD40 module. Disabled by default. Adjusted by the SCD40 Temperature Offset .
SCD40 Humidity
60s
Humidity from the optional SCD40 module. Disabled by default. Adjusted by the SCD40 Humidity Offset .
LTR390 Light
60s
Ambient light level in lux from the LTR390.
LTR390 UV Index
60s
UV index measured by the LTR390.
Combined presence
Sensor
Default Update
Details
Combined Presence
real-time
Combined occupancy: shows Detected when either the LD2450 or the LD2412 radar sees a target, and Clear when neither does. Use this entity for automations and dashboards instead of the individual radar presence sensors.
Radar presence (LD2412 mmWave)
Sensor
Default Update
Details
LD2412 Presence
real-time
Whether the LD2412 detects any target, moving or still.
LD2412 Moving Target
real-time
Whether the LD2412 detects only a moving target.
LD2412 Still Target
real-time
Whether the LD2412 detects only a still target.
LD2412 Detection Distance
real-time
Distance of the target being tracked. Disabled by default.
LD2412 Moving Distance
real-time
Distance of the moving target being tracked. Disabled by default.
LD2412 Still Distance
real-time
Distance of the still target being tracked. Disabled by default.
LD2412 Move Energy
real-time
Energy level of the moving target being tracked. Disabled by default.
LD2412 Still Energy
real-time
Energy level of the still target being tracked. Disabled by default.
LD2412 Light
real-time
Light level reported by the LD2412. Disabled by default.
Radar tracking (LD2450 mmWave)
Sensor
Default Update
Details
LD2450 Presence
real-time
Whether the radar currently detects any target. Great for occupancy automations.
LD2450 Moving Target
real-time
Whether a moving target is detected.
LD2450 Still Target
real-time
Whether a stationary target is detected.
LD2450 Presence Target Count
real-time
Count of all presence targets (max 3).
LD2450 Moving Target Count
real-time
Count of all moving targets (max 3).
LD2450 Still Target Count
real-time
Count of all still targets (max 3).
LD2450 Target-1 / Target-2 / Target-3 X
real-time
Distance in mm of the target from the sensor along the X-axis (negative = left, positive = right, range -3000 to 3000).
LD2450 Target-1 / Target-2 / Target-3 Y
real-time
Distance in mm of the target from the sensor in the Y direction (near/far, range 0 to 6000).
LD2450 Target-1 / Target-2 / Target-3 Speed
real-time
Speed of the moving target in mm/s.
LD2450 Target-1 / Target-2 / Target-3 Angle
real-time
Angle of the target in degrees relative to the sensor.
LD2450 Target-1 / Target-2 / Target-3 Distance
real-time
Straight-line distance of the target from the sensor.
LD2450 Target-1 / Target-2 / Target-3 Resolution
real-time
Target detection range resolution in mm. Disabled by default.
LD2450 Target-1 / Target-2 / Target-3 Direction
real-time
Direction of the target: Stationary, Moving away, Approaching, or NA.
LD2450 Zone-1 / Zone-2 / Zone-3 All Target Count
real-time
Total targets in the zone, stationary or moving.
LD2450 Zone-1 / Zone-2 / Zone-3 Moving Target Count
real-time
Count of moving targets in the zone.
LD2450 Zone-1 / Zone-2 / Zone-3 Still Target Count
real-time
Count of stationary targets in the zone.
General
Setting
Default
What it does
ESP Reboot
—
Restarts the device. Helpful for troubleshooting or refreshing the connection.
Firmware Type
WiFi / Ethernet
Switches between the Wi-Fi and Ethernet firmware without re-flashing. After picking the firmware you want, press Firmware Update to apply it.
Reduce DB Reporting
Off
Filters several entities so they only report when a threshold is met, using less Wi-Fi airtime and less Home Assistant database space.
SCD40 Temperature Offset
18.86 °C
Calibration offset for the SCD40 temperature reading. Disabled by default.
SCD40 Humidity Offset
0 %
Calibration offset for the SCD40 humidity reading. Disabled by default.
SCD40 Automatic Self Calibration
On
Lets the SCD40 self-calibrate over time against the lowest CO₂ it sees. Disabled by default.
LD2412 radar
Setting
Default
What it does
LD2412 Bluetooth
—
Toggles the LD2412's Bluetooth so you can connect with the HLK Radartool phone app for tuning. Turn it back off when finished.
LD2412 Engineering Mode
—
Enables the g00 to g13 move and still energy readouts used for mmWave tuning .
LD2412 Timeout
—
Seconds the LD2412 presence stays detected after the target is lost.
LD2412 min distance gate
—
Minimum distance gate for detection.
LD2412 max distance gate
—
Maximum distance gate for detection.
LD2412 g00 to g13 move threshold
—
Movement sensitivity threshold for each 0.75 m gate, from gate 0 (nearest) to gate 13. Raise a gate's value to tune out false motion at that distance.
LD2412 g00 to g13 still threshold
—
Stillness sensitivity threshold for each 0.75 m gate, from gate 0 (nearest) to gate 13.
LD2412 Factory Reset
—
Restores the LD2412's move and still thresholds to the manufacturer defaults.
LD2412 Light Threshold
—
Light level threshold for the LD2412. Disabled by default.
LD2412 Light Function
—
Selects how the LD2412 uses its light reading. Disabled by default.
LD2412 Hardware output pin level
—
Output pin level for the LD2412. Disabled by default.
LD2412 Distance resolution
—
Distance resolution for the LD2412. Disabled by default.
LD2412 baud rate
from module
Serial baud rate the LD2412 uses to talk to the R-PRO-1 (default 115200). Disabled by default; no need to change.
LD2450 radar
Setting
Default
What it does
LD2450 Bluetooth
—
Toggles the LD2450's Bluetooth so you can connect with the HLK Radartool phone app for tuning. Turn it back off when finished.
LD2450 Multi Target Tracking
from module
Turns multi-target tracking on or off. Initial state is read from the LD2450 at boot. Disabled by default.
LD2450 Timeout
—
Seconds the LD2450 presence stays detected after the target is lost.
LD2450 Zone Type
Disabled
Zone detection mode: Disabled, Detection (only detect targets inside the zone), or Filter (exclude the zone from detection).
LD2450 Zone-1 / Zone-2 / Zone-3 X1, X2
—
Start and end X coordinates of the zone in mm (-3000 left to 3000 right).
LD2450 Zone-1 / Zone-2 / Zone-3 Y1, Y2
—
Start and end Y coordinates of the zone in mm (0 to 6000).
LD2450 Factory Reset
—
Resets the LD2450 radar module to its factory settings.
LD2450 Baud rate
from module
Serial baud rate the LD2450 uses to talk to the R-PRO-1 (default 256000). Disabled by default; no need to change.
Entity
Default Update
What it shows
Apollo Firmware Version
on boot
The Apollo firmware build installed on the device (for example, 26.3.2.1).
ESPHome Version
on boot
The ESPHome version the firmware was compiled with.
Firmware Update
—
Shows whether a firmware update is available and lets you update from inside Home Assistant.
IP Address
on connect
The device's IP address on your network (Wi-Fi firmware).
Online
on change
Connection status of the device to Home Assistant.
ESP Temperature
60s
Internal temperature of the ESP32 chip. Runs warmer than the room because of the processor and Wi-Fi radio. Disabled by default.
Uptime
60s
How long the device has been running since its last reboot.
LD2412 Dynamic Background Correction Status
real-time
Whether the LD2412 is running dynamic background correction.
LD2412 Out Pin
real-time
State of the LD2412 hardware output pin. Disabled by default.
LD2412 Firmware
on boot
Firmware version installed on the LD2412 radar module. Disabled by default.
LD2412 BT MAC
on boot
Bluetooth MAC address of the LD2412 radar module. Disabled by default.
LD2412 g00 to g13 move energy
real-time
Live move energy for each gate (g00 to g13), used when tuning with Engineering Mode.
LD2412 g00 to g13 still energy
real-time
Live still energy for each gate (g00 to g13), used when tuning with Engineering Mode.
LD2412 Query params
—
Queries the LD2412's current parameters for debugging or advanced setup.
LD2412 Restart
—
Restarts the LD2412 radar module.
LD2412 Start Dynamic Background Correction
—
Kicks off a dynamic background correction pass on the LD2412.
LD2450 Firmware
on boot
Firmware version installed on the LD2450 radar module. Disabled by default.
LD2450 BT MAC
on boot
Bluetooth MAC address of the LD2450 radar module. Disabled by default.
LD2450 Restart
—
Restarts the LD2450 radar module.